To convert data into lb/ft2, divide on center spacing of component into lb/ft. ▲ Limited by safety factor of 2.
Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions
Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
200.XXZ.01 207.01H
211.01Z 209.01Z
299.01H 207.01H
250.01Z 254.01Z
270.XXZ.01 254.01Z
1’ x 4’
32.4
56.4
55.6
67.6
2’ x 2’
29.2
34.8
49.6
52.8
2’ x 4’
40.8
47.2
64.0▲
76.0▲
2’ x 5’
40.8
3’ x 3’
63.0▲
20” x 48”
37.6
20” x 60”
37.6
Consult specific U.L. design for allowable lighting configurations. ▲ Limited by safety factor of 2.
Fire Rated Assemblies
Hanger Positions for Fire Rated Situations This illustrates hanger positions for single fixtures in a field and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area.
Non-Fire Rated Assemblies
Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures.
Environment
Materials and Resources (MR) -Waste Management Planning -Interiors Life Cycle Impact Reduction -Environmental Product Declarations -Sourcing of Raw Materials -Material Ingredients -Waste Management Indoor Environmental Quality (EQ) -Low-Emitting Materials -Interior Lighting -Acoustic Performance
Back
Component Load Test Data and Material
Main Tee
Length
Allowable Load per ASTM C635
Hanger Spacing
4'
5'
6'
Cross Tee
Length
20"
2'
30"
3'
4'
200.XXZ.01
144"
HD
8.9
5.6
207.01H
60"
209.01Z
48"
9.1
211.01Z
144"
ID
6.0
4.0
216.01H
120"
ID
6.3
3.9
229.01Z
24"
32.5▲
250.01Z
144"
ID
6.3
3.9
251.01H
12"
252.01Z
24"
41.0▲
253.01H
36"
34.7
254.01Z
48"
14.1
257.01Z
20"
90.0▲
258.01H
30"
57.4
270.XXZ.01
144"
HD
8.9
5.6
278.01H
96"
299.01H
120"
ID
6.0
4.0
To convert data into lb/ft2, divide on center spacing of component into lb/ft. ▲ Limited by safety factor of 2.
Light Fixture Load Test Data (based on 1/360 span deflection)
Dimensions
Light Fixtures
Main & Cross Tees - Allowable Fixture Weight – Pounds
200.XXZ.01 207.01H
211.01Z 209.01Z
299.01H 207.01H
250.01Z 254.01Z
270.XXZ.01 254.01Z
1’ x 4’
32.4
56.4
55.6
67.6
2’ x 2’
29.2
34.8
49.6
52.8
2’ x 4’
40.8
47.2
64.0▲
76.0▲
2’ x 5’
40.8
3’ x 3’
63.0▲
20” x 48”
37.6
20” x 60”
37.6
Consult specific U.L. design for allowable lighting configurations. ▲ Limited by safety factor of 2.